Incoming Inspection for Starch Powders: Sampling Bags and Testing Moisture
The short answer
A test is only as good as the sample. For each delivery of starch, dextrin or gum powder:
- Sample several bags, chosen across the lot (top, middle and door-side pallets), and from the inside of each bag, not just the surface.
- Test moisture by the reference oven method for starch, ISO 1666 (130 °C, atmospheric pressure) [1], or by a quick moisture balance that you have correlated against it.
- Compare with the COA and your agreed limit, then accept, hold or reject.
Sampling: the step most plants skip
Powder in bags is not uniform. Bags near container doors or on top layers can pick up moisture in transit (see why dextrin cakes in transit), and the surface of a bag differs from its core.
India’s draft dextrin standard sets out a lot-based sampling plan. Bags are selected from each lot, the main characteristics are tested on a composite sample, and dextrin content is tested on individual samples [2]. A practical version for a plant:
| Step | How |
|---|---|
| Choose bags | Spread across the lot: top, middle, bottom layers; door end and far end |
| Take increments | Use a sampling spear (trier) to draw powder from the depth of each bag |
| Seal at once | Airtight containers or bags, labelled with lot, bag and date |
| Make a composite | Mix equal increments for routine tests |
| Keep individual samples | For any bag that looks damp, lumpy or discoloured |
| Retain | Keep a sealed retained sample of each lot until it is used up |
Moisture: reference method and quick method
| Method | What it is | Use it for |
|---|---|---|
| Oven method, ISO 1666 | Drying native or modified starch at 130 °C at atmospheric pressure, and weighing the loss [1] | Reference results; disputes with suppliers |
| Halogen or infrared moisture balance | Heats and weighs continuously; results in minutes | Routine checks, after correlating against the oven method on your products |
Why moisture matters:
- You pay for water. Dextrin is typically sold at about 8–14% moisture [3, p. 230]; India’s draft standard caps dextrin moisture at 10% [2].
- Damp powder cakes and can affect glue solids.
What else to check on arrival
- Bag condition: wet patches, tears, stains, caking.
- Labels: product name, lot number and net weight match the COA. India’s draft standard requires bags to be marked with the material name, manufacturer, net mass, type and a packing code or serial number [2].
- A quick performance check: make a small batch of your glue or size, and compare viscosity with your retained standard sample (see measuring glue viscosity).
- Smell and colour: musty or sour smells and unusual colour mean the lot should be held.
Accept, hold or reject
| Result | Action |
|---|---|
| Within agreed limits, labels match | Accept; file the COA and your results |
| Slightly out on moisture, no caking | Hold; retest a fresh composite; discuss with the supplier |
| Caked, damp or wrong lot | Reject the affected bags; photograph them; notify the supplier and insurer with results |
FAQ
What temperature is used to test starch moisture? ISO 1666 specifies oven drying at 130 °C at atmospheric pressure for native or modified starch [1].
How many bags should I sample? Enough to cover the lot. Spread your selection across layers and positions. India’s draft dextrin standard gives a lot-based sampling scheme [2]. Agree a plan with your supplier.
Is a moisture balance accurate enough? Yes, for routine checks, once you have correlated it with the oven method on your own products.
Want to check our lots yourself? Every Shalbond lot carries a COA with its moisture result. Ask us for the test method and a retained-sample policy that matches your inspection plan. Contact us or email info@shalbond.com.